<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-07 03-40-34
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.70 MHz 5/5, 48 dBuV R-PCE
Pilot RDS Phase Difference
6.0 kHz 3.2 kHz -87 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
16 kHz 47 kHz 19003 0,0421
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,4 dBr -0,97 dBr -0,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PCE " 280C 9 (Varied) 1 0 1 5 3:40, 7.05.2024
RT
"Zpravy z regionu - rozhovory - dobre rady - souteze "
AF EON
88.9, 93.7, 98.6, 101.0, 102.4, 103.3, 104.7 MHz -
FM Scope Max at: 47 kHz MIN: 16 kHz % above 77 kHz: 0,0421 Acquired: 2024/05/07 3:40:31 Total samples: 19003 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: -0,3 dBr MIN: -2,4 dBr AVE: -0,97 dBr % above 0,2 dBr: 0,0 Last value: -0,4 dBr (2024/05/07 3:40:31) 03:26 03:28 03:30 03:32 03:34 03:36 03:38 03:40 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality